New & Used Rad Room, Analog
Market Value Calculator
Manufacturer
Continent
Condition
Manf. Year From
Manf. Year Until
Price Range (USD)
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Digital,X-ray Generator,Chest X-ray,Rad/Fluoro Room, Image Intensifier
- Complete Systems (146)
- Parts (4,670)
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look
Device: Rad Room, Analog
Manufacturer: Philips
Model: Bucky DIAGNOST CE
Manufacturer: Philips
Model: Bucky DIAGNOST CE
Location: France, Île-de-France
17,454


2002

Quick Look
Device: Rad Room, Analog
Manufacturer: Toshiba
Model: Ultimax MDX-8000A
Manufacturer: Toshiba
Model: Ultimax MDX-8000A
Location: Germany, Bavaria
18,618
2006

Quick Look
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX TOP ACSS
Manufacturer: Siemens
Model: MULTIX TOP ACSS
Location: Romania, Neam
13,381
2009

Quick Look
Device: Rad Room, Analog
Manufacturer: Siemens
Model: AXIOM Vertix MD Trauma
Manufacturer: Siemens
Model: AXIOM Vertix MD Trauma
Location: Poland, Zachodniopomorskie
15,709
-

Quick Look
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX UH
Manufacturer: Siemens
Model: MULTIX UH
Location: Germany, Hamburg
2,560
-

Quick Look
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: Proteus XR/a
Manufacturer: GE Healthcare
Model: Proteus XR/a
Location: United States, Minnesota
39,000


2012

Quick Look
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: SFX II
Manufacturer: GE Healthcare
Model: SFX II
Location: United States, Florida
1,000


1989

Quick Look
Device: Rad Room, Analog
Manufacturer: Shandong Xinua
Model: SHS105B
Manufacturer: Shandong Xinua
Model: SHS105B
Location: China, Shandong
22,500


-

Quick Look
Device: Rad Room, Analog
Manufacturer: Arcoma
Model: ARCO SPHERE
Manufacturer: Arcoma
Model: ARCO SPHERE
Location: Italy, Florence
9,308
1997

Quick Look
Device: Rad Room, Analog
Manufacturer: Philips
Model: Bucky DIAGNOST VE VT
Manufacturer: Philips
Model: Bucky DIAGNOST VE VT
Location: Italy, Milan
10,471
2004

Quick Look
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX
Manufacturer: Siemens
Model: MULTIX
Location: Italy, Florence
8,144
-

Quick Look
Device: Rad Room, Analog
Manufacturer: Picker
Model: CLINIX-R
Manufacturer: Picker
Model: CLINIX-R
Location: United States, Texas
9,700


1995

Quick Look
Device: Tomographic X-ray
Manufacturer: Philips
Model: Bucky DIAGNOST TH
Manufacturer: Philips
Model: Bucky DIAGNOST TH
Location: Italy, Verona
2,793
2003

Quick Look
Device: Rad Room, Analog
Manufacturer: Picker
Model: Clinix-E
Manufacturer: Picker
Model: Clinix-E
Location: United States, Ohio
Rating: 100%
Rating: 100%
6,500


-

Quick Look
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX T
Manufacturer: Siemens
Model: MULTIX T
Location: Netherlands, Zuid-Holland
10,182
1999
Rad Room, Analog may also be referred to as :
Film Radiography | Control Unit | X-ray Table | X-ray Tube | Rad Room, Film | Film/CR Radiographic System | X-ray Generator | Cassette Holder | Film Radiographic System | Radiology, Film | Radiographic Table System, FilmTips for buying Rad Room, Analog
- When choosing an Analog Rad room, storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of CR Radiographic Systems over film-based radiography.
- The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
- The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
- Digital or CR radiographic systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
- The detector is fixed in the radiographic table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright systems can be tilted to allow table based exams.
- Facilities should evaluate all types of examinations being performed before deciding which type of Analog Rad Room will better suit their needs. The number and types of procedures will influence the features selected for the system.
- Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the radiographic table system’s overall procedural capabilities.
- Departments handling trauma and emergency cases may prefer elevating tables because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
- Bucky systems for both tilting and non-tilting tables should be motorized.
- To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
- Buyers should look into the Analog Rad Room system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
- Buyers of Analog Rad Rooms should consider generator options as well; high-frequency generators need less space and often eliminate the need for high-voltage cables.
- To facilitate future additions to any network, compatibility with DICOM 3.0 is a requirement for all newly purchased equipment (including storage devices).
- Suppliers must provide DICOM conformance statements that explain in detail what information objects, service classes, and data encoding are supported by the Analog Rad Room system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>