New & Used Rad Room, Analog

Market Value Calculator
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Digital,X-ray Generator,Chest X-ray,Rad/Fluoro Room, Image Intensifier
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX Swing
Premium User
Location: Romania, Bucharest
58,332
This Seller accepts SafeTrade as a payment method
2009

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX
Location: Brazil, Sao Paulo
25,000
This Seller accepts SafeTrade as a payment method
1997

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX Compact K
Location: Czech Republic, Ustecky
8,860
1999

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Philips
Model: Horizontal DIAGNOST H
Location: Germany, Baden-Wurttemberg
4,936
-

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Philips
Model: Bucky DIAGNOST TH
Location: United States, Florida
21,900
1999

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX UH
Location: Germany, Hamburg
3,797
This Seller accepts SafeTrade as a payment method
1994

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Listem
Model: CSM-21
Location: United States, Texas
10,800
2004

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Picker
Model: CLINIX-R
Location: United States, Texas
9,700
This Seller accepts SafeTrade as a payment method
1995

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Picker
Model: Clinix-E
Location: United States, Ohio
Rating: 100%
6,500
This Seller accepts SafeTrade as a payment method
-

Quick Look

 
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: PRESTILIX Remote 1600X
Location: France, Île-de-France
31,641
1996

Quick Look

 
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: Powerpax 40
Location: France, Provence-Alpes-Côte-d'Azur
Rating: 100%
10,758
1997

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Philips
Model: Bucky Diagnost VE
Location: Czech Republic, Stredocesky
15,000
2001

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: POLYDOROS LX
Location: United Arab Emirates
7,000
This Seller accepts SafeTrade as a payment method
1999

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Amrad
Model: 325R
Location: United States, California
4,000
This Seller accepts SafeTrade as a payment method
1986

Quick Look

 
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: Compax 40E
Location: United States, Ohio
Rating: 100%
7,500
This Seller accepts SafeTrade as a payment method
2000
Page: 1 2 3 4 5

Rad Room, Analog may also be referred to as :

Film Radiography | Control Unit | X-ray Table | X-ray Tube | Rad Room, Film | Film/CR Radiographic System | X-ray Generator | Cassette Holder | Film Radiographic System | Radiology, Film | Radiographic Table System, Film
 

Tips for buying Rad Room, Analog

  1. When choosing an Analog Rad room, storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of CR Radiographic Systems over film-based radiography.
  2. The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
  3. The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
  4. Digital or CR radiographic systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
  5. The detector is fixed in the radiographic table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright systems can be tilted to allow table based exams.
  6. Facilities should evaluate all types of examinations being performed before deciding which type of Analog Rad Room will better suit their needs. The number and types of procedures will influence the features selected for the system.
  7. Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the radiographic table system’s overall procedural capabilities.
  8. Departments handling trauma and emergency cases may prefer elevating tables because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
  9. Bucky systems for both tilting and non-tilting tables should be motorized.
  10. To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
  11. Buyers should look into the Analog Rad Room system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
  12. Buyers of Analog Rad Rooms should consider generator options as well; high-frequency generators need less space and often eliminate the need for high-voltage cables.
  13. To facilitate future additions to any network, compatibility with DICOM 3.0 is a requirement for all newly purchased equipment (including storage devices).
  14. Suppliers must provide DICOM conformance statements that explain in detail what information objects, service classes, and data encoding are supported by the Analog Rad Room system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>