New & Used Rad Room, Analog

Market Value Calculator
 
Applied Filters

Manf. Year From : 2008

  Reset
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Digital,X-ray Generator,Chest X-ray,Rad/Fluoro Room, Image Intensifier
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX TOP ACSS
Location: Romania, Neam
13,381
2009

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Philips
Model: Essenta RAD
Location: United States, New Jersey
Negotiable
2009

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Bennett X-ray
Model: HFQ 100Khz
Location: United Kingdom, Stirling
3,200
2010

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Polycom
Model: C-2200
Location: Turkey, Ankara
12,000
2012

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Summit
Model: L500-3
Location: United States, New Jersey
Negotiable
2008

Quick Look

Brand New Item
Device: Rad Room, Analog
Manufacturer: Siemens
Model: Multix B
Location: Venezuela, Distrito Capital
30,000
2015

Quick Look

Brand New Item
Device: Rad Room, Analog
Manufacturer: Imago Radiology
Model: Multigraph IMX-8
Location: Italy, Milan
8,378
This Seller accepts SafeTrade as a payment method
2017

Quick Look

 
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: Proteus XR/a
Location: Indonesia, Sumatera Utara
8,000
2012

Quick Look

Brand New Item
Device: Rad Room, Analog
Manufacturer: Imago Radiology
Model: Antarix Elevator IMX-4B Non-Tomographic Unit
Location: Italy, Milan
10,240
This Seller accepts SafeTrade as a payment method
2017

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Siemens
Model: MULTIX Swing
Location: Turkey, Istanbul
582
This Seller accepts SafeTrade as a payment method
2008

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Quantum Medical Imaging
Model: Q-Rad SQ
Location: Russia, Nizhegorod
51,000
2008

Quick Look

 
Device: Rad Room, Analog
Manufacturer: GE Healthcare
Model: Proteus XR/i
Location: Poland, Lodzkie
10,500
2008

Quick Look

 
Device: Rad Room, Analog
Manufacturer: Philips
Model: Bucky DIAGNOST TH
Location: United States, New Jersey
Negotiable
2011

Quick Look

 
Device: CR System
Manufacturer: Fuji
Model: FCR 9000
Location: Pakistan, Punjab
4,800
This Seller accepts SafeTrade as a payment method
2016

Quick Look

 
Device: CR System
Manufacturer: Fuji
Model: FCR 9000
Location: Pakistan, Punjab
4,500
This Seller accepts SafeTrade as a payment method
2016
Page: 1 2 3

Rad Room, Analog may also be referred to as :

Film Radiography | Control Unit | X-ray Table | X-ray Tube | Rad Room, Film | Film/CR Radiographic System | X-ray Generator | Cassette Holder | Film Radiographic System | Radiology, Film | Radiographic Table System, Film
 

Tips for buying Rad Room, Analog

  1. When choosing an Analog Rad room, storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of CR Radiographic Systems over film-based radiography.
  2. The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
  3. The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
  4. Digital or CR radiographic systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
  5. The detector is fixed in the radiographic table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright systems can be tilted to allow table based exams.
  6. Facilities should evaluate all types of examinations being performed before deciding which type of Analog Rad Room will better suit their needs. The number and types of procedures will influence the features selected for the system.
  7. Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the radiographic table system’s overall procedural capabilities.
  8. Departments handling trauma and emergency cases may prefer elevating tables because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
  9. Bucky systems for both tilting and non-tilting tables should be motorized.
  10. To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
  11. Buyers should look into the Analog Rad Room system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
  12. Buyers of Analog Rad Rooms should consider generator options as well; high-frequency generators need less space and often eliminate the need for high-voltage cables.
  13. To facilitate future additions to any network, compatibility with DICOM 3.0 is a requirement for all newly purchased equipment (including storage devices).
  14. Suppliers must provide DICOM conformance statements that explain in detail what information objects, service classes, and data encoding are supported by the Analog Rad Room system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>