Parts: Rad Room, Analog, GE Healthcare, IBIS III table

Applied Filters

Manufacturer : GE Healthcare

  Reset

Model : IBIS III table

  Reset
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Digital,X-ray Generator,Chest X-ray,Rad/Fluoro Room, Image Intensifier
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured
Page: 1 2 3 4

Rad Room, Analog may also be referred to as :

Film Radiography | Control Unit | X-ray Table | X-ray Tube | Rad Room, Film | Film/CR Radiographic System | X-ray Generator | Cassette Holder | Film Radiographic System | Radiology, Film | Radiographic Table System, Film

If you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (25):

 
Item Details
Actions
30c3299 board y685189

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: 30c3299 board / y685189

cu3 board a4301180b

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: cu3 board / a4301180b

cz2 board a04301210c

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: cz2 board / a04301210c

e01 board y714456

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: e01 board / y714456

e02 board y714475

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: e02 board / y714475

e03 board y714615

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: e03 board / y714615

e04 board y714563

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: e04 board / y714563

e14 board a04301080d

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: e14 board / a04301080d

ec3 board a04301010e

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: ec3 board / a04301010e

ee4 board a04301040a

Device: Rad Room, Analog

Manufacturer: GE Healthcare

Model: IBIS III table

Name / Number: ee4 board / a04301040a

Page: 1 2 3
 

Tips for buying Rad Room, Analog Parts

  1. When choosing an Analog Rad room, storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of CR Radiographic Systems over film-based radiography.
  2. The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
  3. The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
  4. Digital or CR radiographic systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
  5. The detector is fixed in the radiographic table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright systems can be tilted to allow table based exams.
  6. Facilities should evaluate all types of examinations being performed before deciding which type of Analog Rad Room will better suit their needs. The number and types of procedures will influence the features selected for the system.
  7. Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the radiographic table system’s overall procedural capabilities.
  8. Departments handling trauma and emergency cases may prefer elevating tables because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
  9. Bucky systems for both tilting and non-tilting tables should be motorized.
  10. To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
  11. Buyers should look into the Analog Rad Room system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
  12. Buyers of Analog Rad Rooms should consider generator options as well; high-frequency generators need less space and often eliminate the need for high-voltage cables.
  13. To facilitate future additions to any network, compatibility with DICOM 3.0 is a requirement for all newly purchased equipment (including storage devices).
  14. Suppliers must provide DICOM conformance statements that explain in detail what information objects, service classes, and data encoding are supported by the Analog Rad Room system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>