Parts: Rad Room, Digital, Siemens

Applied Filters

Manufacturer : Siemens

  Reset
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Analog,X-ray Generator
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured
Page: 1 2 3

Rad Room, Digital may also be referred to as :

Rad Room, Digital | Flat Panel, Radiographic System | Digital Radiography | Radiographic Table System, Digital

If you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (7):

 
Item Details
Actions
Collimator  83-75-024-G2107

Device: Rad Room, Digital

Manufacturer: Siemens

Model: AXIOM MULTIX MT

Name / Number: Collimator / 83-75-024-G2107

Machelt Collimator

Device: Rad Room, Digital

Manufacturer: Siemens

Model: AXIOM MULTIX MT

Name / Number: Machelt Collimator

D21 BD 8378150

Device: Rad Room, Digital

Manufacturer: Siemens

Model: Vertix FD

Name / Number: D21 BD / 8378150

D31 BOARD 5757732

Device: Rad Room, Digital

Manufacturer: Siemens

Model: Vertix FD

Name / Number: D31 BOARD / 5757732

ENCODER 4698502

Device: Rad Room, Digital

Manufacturer: Siemens

Model: Vertix FD

Name / Number: ENCODER / 4698502

KK interface SX radiograph unit D292 3827297

Device: Rad Room, Digital

Manufacturer: Siemens

Model: Vertix FD

Name / Number: KK interface SX radiograph unit D292 / 3827297

PLATE 45054

Device: Rad Room, Digital

Manufacturer: Siemens

Model: Vertix FD

Name / Number: PLATE / 45054

 

Tips for buying Rad Room, Digital Parts

  1. Storage space reduction, enhanced image processing, and off-site diagnostic capabilities are some of the advantages of digital rad rooms over film-based radiography.
  2. The tilting tables allow a wide range of tilting movements from -15° to +90° and have an average speed of 6°/sec. Horizontal-to-vertical tilt should average 15 sec.
  3. The non-tilting tables specify a wide range of tabletop motions but do not allow tilting angles.
  4. Digital radiographic table systems generally perform upright examinations or table-based examinations, for which detector mounting is crucial.
  5. The detector is fixed on the digital radiographic table system in table-based units, preventing certain examinations due to patient positioning constraints. Some upright digital radiography systems can be tilted to allow table based exams.
  6. Facilities should evaluate all types of examinations being performed before deciding which type of digital rad rooms will better suit their needs. The number and types of procedures will influence the features selected for the system.
  7. Smaller focal-spot sizes can provide better spatial resolution on film for certain studies, and options such as tomography and table tilt can increase the digital rad room system’s overall procedural capabilities.
  8. Departments handling trauma and emergency cases may prefer elevating tables, because the table height can be adjusted to facilitate patient transfer from a mobile stretcher or a wheelchair.
  9. Bucky systems for both tilting and non-tilting tables should be motorized.
  10. To ensure acceptable film darkening, a three-field AEC device is recommended. Grid ratios should be 10:1 or higher. Grids with higher ratios provide higher image quality.
  11. Buyers of digital radiography should look into the digital rad room system’s integration into picture archiving and communication systems (PACS) already in use in the facility.
  12. Buyers of digital rad rooms should consider generator options as well; high-frequency generators need less space and often eliminate the need for high-voltage cables.
  13. To facilitate future additions to any digital radiography network, compatibility with DICOM 3.0 is a requirement for all newly purchased digital radiography equipment (including storage devices).
  14. Suppliers must provide DICOM conformance statements that explain in detail which information objects, service classes, and data encodings are supported by the system. The statements should be inspected by specialists, and should share the same format and vocabulary to facilitate comparisons between suppliers.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>