Parts: Radiographic Photospot Camera, GE Healthcare

 
Applied Filters

Manufacturer : GE Healthcare

  Reset
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Radiographic Photospot Camera may also be referred to as :

X-ray Photospot Unit | X-ray Photospot | System, X-ray, Photofluorographic | Radiographic/Fluoroscopic Table System | Photospot | Photofluoroscope | Fluoroscope

If you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (4):

 
Item Details
Actions
input data logic assy 46214038

Device: Radiographic Photospot Camera

Manufacturer: GE Healthcare

Model: Quantamatic TX

Name / Number: input data logic assy / 46214038

message storage assy; g1a 46214040

Device: Radiographic Photospot Camera

Manufacturer: GE Healthcare

Model: Quantamatic TX

Name / Number: message storage assy; g1a / 46214040

rocker switch 4573

Device: Radiographic Photospot Camera

Manufacturer: GE Healthcare

Model: Quantamatic TX

Name / Number: rocker switch / 4573

switch assy 46184179G2

Device: Radiographic Photospot Camera

Manufacturer: GE Healthcare

Model: Quantamatic TX

Name / Number: switch assy / 46184179G2


Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
  • Fill in a simple form, giving us details about the medical device you are searching for.
  • Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
  • Choose the best and most suitable quote for you!
Post a Buying Request >>
 

Tips for buying Radiographic Photospot Camera Parts

  1. Before purchasing a radiographic photospot camera, medical facilities should consider the types of procedures to be performed and determine the table tilt, travel, image intensifier size, and image processing methods that will best suit their needs.
  2. X-ray photospot unit purchasers should also look into the following issues: heat dissipation rate, and heat capacity of the x-ray tube anode.
  3. In any given tube, only 0.2% of the electrical energy delivered to the anode is converted to x-rays; the rest is converted to heat, which if not quickly dissipated, will destroy the anode.
  4. Photofluoroscope digital cameras are used to capture both fluoroscopic and fluorographic images taken during fluoroscopic exams.
  5. In order to meet the needs of both photofluoroscopic and photospot images, specifications for x-ray photospot unit cameras must be as high as possible.
  6. For some advanced interventional procedures that require longer imaging times, high heat capacity tubes are especially important. The anode heat capacity should be at least 350,000 heat units.
  7. Buyers of radiographic photospot cameras need to consider the focal spot size of the anode. A smaller focal spot provides better quality images but does not dissipate heat as well as a larger one. It also requires a larger anode heat capacity than a larger focal spot does.
  8. Magnification angiographies require a focal spot size of 0.3 mm or less, while larger sizes are ideal for investigating chemic heart disease.
  9. To accommodate the many different procedures performed, facilities may need additional equipment such as patient monitors, defibrillators, contrast injectors, software for specific imaging such as cardiac or vascular, and emergency resuscitation devices.