Parts: Spot Film Device
![]() |
Medical Part Finder | ![]() |
Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! |
Go to Part Finder >> |
- Parts (1,679)

Quick Look
Manufacturer: Philips
Model: DSI
Name / Number: keyboard / 4522 300 05656
Rating: 93%

Quick Look
Manufacturer: Philips
Model: DSI
Name / Number: DSI keyboard assy. ACQ + view (BLM) / 4522 300 05656

Quick Look
Manufacturer: Picker
Model: 1730
Name / Number: cirque smart cat / GDB410


Quick Look
Manufacturer: GE Healthcare
Model: 88-35 SFD
Name / Number: control assy / 46187912G2


Quick Look
Manufacturer: GE Healthcare
Model: 88-35 SFD
Name / Number: ion chamber / T3481G


Quick Look
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D2 BOARD / 1674006

Quick Look
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D2 BOARD / 1674006

Quick Look
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: HOST PC / 1286074

Quick Look
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D33 BOARD / 1199293

Quick Look
Manufacturer: GE Healthcare
Model: 63 SFD
Name / Number: head end cover; safety switch actuator / 46180742P1


Quick Look
Manufacturer: GE Healthcare
Model: 88 SFD
Name / Number: servo motor; motor pulley assy / 46194594P1


Quick Look
Manufacturer: GE Healthcare
Model: 88-35 SFD
Name / Number: Mask drive pcb / 46188778G1



Quick Look
Manufacturer: Picker
Model: 1719c
Name / Number: microswitch / T29A16


Quick Look
Manufacturer: Picker
Model: 1720
Name / Number: fuse- lamp, 250v slo blow / T272


Quick Look
Manufacturer: Picker
Model: 1721D
Name / Number: control deck assy / 354769d

Spot Film Device may also be referred to as :
Digital Photospot System | X-ray Fluoroscope | X-ray Fluorograph | System, X-ray, Photofluorographic | Radiographic/Fluoroscopic Table System | Photofluoroscopes | Fluoroscopes | FluorographIf you have not found your required medical part on the above list, our suppliers can additionally offer you the following medical parts (152):

Device: Spot Film Device
Manufacturer: GE Healthcare
Model: 85-35 SFD
Name / Number: 10 - 1 ratio motor / 46250537
Request a quote

Device: Spot Film Device
Manufacturer: GE Healthcare
Model: 63 SFD
Name / Number: 2 Position Button / 46124948G1
Request a quote

Device: Spot Film Device
Manufacturer: GE Healthcare
Model: 63 SFD
Name / Number: 4 Position Button / 46148328G2
Request a quote

Device: Spot Film Device
Manufacturer: GE Healthcare
Model: 85-35 SFD
Name / Number: 4-way table top switch / 46232150
Request a quote

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: 7x7 digital filter (60202157) / 97202157
Request a quote

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: alu board in room (60202103) / 9720216301
Request a quote

Device: Spot Film Device
Manufacturer: GE Healthcare
Model: 85-35 SFD
Name / Number: amplifier pcb / 46225674g1
Request a quote

Device: Spot Film Device
Manufacturer: GE Healthcare
Model: 85-35 SFD
Name / Number: angle/det/aux pcb / 46188543g1a
Request a quote

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: back plane bd / 9720124501
Request a quote

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: backplane VME board / 972012450
Request a quote




Tips for buying Spot Film Device Parts
- Facilities should consider the types of procedures to be performed and determine the table tilt, travel, image intensifier size, and image processing methods to best suit those procedures.
- The main consideration for buyers should be the table tilt.
- Tables usually offer a 90° tilt in the plus direction, when feet are down. In the minus directions they offer 15° to 90° tilt.
- Certain procedures, such as cervical myelography, can benefit from a 90°/90° tilt.
- Manufacturers offer various longitudinal and lateral table travels. When deciding on table travel parameters, positioning the patient for various procedures is a major consideration.
- When using larger image intensifiers, more anatomy can be viewed in one image.
- Facilities need to carefully consider their needs when selecting the x-ray generator. The available generators that are commonly used for cardiac imaging include: three phase, 12 pulse, high frequency, and constant-potential generators. All can provide the high power, direct current, or very low ripple waveform required for cinefluorography.
- Space-constrained areas would benefit from high frequency generators, which are smaller and easier to install.
- Facilities should also consider the heat dissipation rate and the heat capacity of the x-ray tube anode. Only 0.2% of the electrical energy delivered to the tube is converted to x-rays, and the rest is radiated as heat - which will destroy the anode if not quickly dissipated.
- To help dissipate the heat, rotating and larger diameter anodes may be used, as well as circulated liquid cooling systems and ceramic tube envelopes.
- Using a higher anode heat capacity allows for longer fluoroscopy runs. It also provides a higher overall output, and extends x-ray tube life.
- The minimum anode heat capacity should be 1,000,000 heat units.
- Advanced interventional procedures requiring longer imaging times would benefit the most from high heat capacity tubes.
- Suppliers now offer x-ray tubes with anode heat capacities over 2,000,000 HU and heat dissipation rates of 900,000 HU/min.
- Buyers need to look at the focal spot size of the anode; a smaller focal spot provides better quality images, but the larger one dissipates heat better. Therefore, smaller ones need a larger anode heat capacity than larger focal spots do.
- Some suppliers offer two or three focal spot sizes to accommodate the variety of imaging techniques and procedures.