Parts: Spot Film Device, Philips
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
- Parts (209)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: DSI keyboard assy. ACQ + view (BLM) / 4522 300 05656
Manufacturer: Philips
Model: DSI
Name / Number: DSI keyboard assy. ACQ + view (BLM) / 4522 300 05656
Location: Netherlands, Overijssel
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: pioneer optical disc drive / deuh7101
Manufacturer: Philips
Model: DSI
Name / Number: pioneer optical disc drive / deuh7101
Location: United States, Ohio
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: pcb / enp30i
Manufacturer: Philips
Model: DSI
Name / Number: pcb / enp30i
Location: United States, Ohio
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: relay / ir4f
Manufacturer: Philips
Model: DSI
Name / Number: relay / ir4f
Location: United States, Ohio
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: emi filter / std6
Manufacturer: Philips
Model: DSI
Name / Number: emi filter / std6
Location: United States, Ohio
Negotiable
-
Quick Look
Device: Radiographic Photospot Camera
Manufacturer: Philips
Model: DSI
Name / Number: OPTICAL DISK PIONEER / 452210483791
Manufacturer: Philips
Model: DSI
Name / Number: OPTICAL DISK PIONEER / 452210483791
Location: United States
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 149024-002
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 149024-002
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 149101-004
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 149101-004
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 103 39763
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 103 39763
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 104 99065
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 104 99065
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 105 27342
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 105 27342
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 08005
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 08005
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 08101
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 08101
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 08404
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 08404
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 15106
Manufacturer: Philips
Model: DSI
Name / Number: BOARD / 4522 108 15106
Location: United States, New York
Negotiable
-
Spot Film Device may also be referred to as :
Digital Photospot System | X-ray Fluoroscope | X-ray Fluorograph | System, X-ray, Photofluorographic | Radiographic/Fluoroscopic Table System | Photofluoroscopes | Fluoroscopes | FluorographTips for buying Spot Film Device Parts
- Facilities should consider the types of procedures to be performed and determine the table tilt, travel, image intensifier size, and image processing methods to best suit those procedures.
- The main consideration for buyers should be the table tilt.
- Tables usually offer a 90° tilt in the plus direction, when feet are down. In the minus directions they offer 15° to 90° tilt.
- Certain procedures, such as cervical myelography, can benefit from a 90°/90° tilt.
- Manufacturers offer various longitudinal and lateral table travels. When deciding on table travel parameters, positioning the patient for various procedures is a major consideration.
- When using larger image intensifiers, more anatomy can be viewed in one image.
- Facilities need to carefully consider their needs when selecting the x-ray generator. The available generators that are commonly used for cardiac imaging include: three phase, 12 pulse, high frequency, and constant-potential generators. All can provide the high power, direct current, or very low ripple waveform required for cinefluorography.
- Space-constrained areas would benefit from high frequency generators, which are smaller and easier to install.
- Facilities should also consider the heat dissipation rate and the heat capacity of the x-ray tube anode. Only 0.2% of the electrical energy delivered to the tube is converted to x-rays, and the rest is radiated as heat - which will destroy the anode if not quickly dissipated.
- To help dissipate the heat, rotating and larger diameter anodes may be used, as well as circulated liquid cooling systems and ceramic tube envelopes.
- Using a higher anode heat capacity allows for longer fluoroscopy runs. It also provides a higher overall output, and extends x-ray tube life.
- The minimum anode heat capacity should be 1,000,000 heat units.
- Advanced interventional procedures requiring longer imaging times would benefit the most from high heat capacity tubes.
- Suppliers now offer x-ray tubes with anode heat capacities over 2,000,000 HU and heat dissipation rates of 900,000 HU/min.
- Buyers need to look at the focal spot size of the anode; a smaller focal spot provides better quality images, but the larger one dissipates heat better. Therefore, smaller ones need a larger anode heat capacity than larger focal spots do.
- Some suppliers offer two or three focal spot sizes to accommodate the variety of imaging techniques and procedures.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>








