Parts: Spot Film Device, Siemens
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
- Parts (125)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Radiographic Photospot Camera
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D2 BOARD / 1674006
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D2 BOARD / 1674006
Location: United States, Wisconsin
Negotiable
-
Quick Look
Device: Radiographic Photospot Camera
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D2 BOARD / 1674006
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D2 BOARD / 1674006
Location: United States, Wisconsin
Negotiable
-
Quick Look
Device: Radiographic Photospot Camera
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: HOST PC / 1286074
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: HOST PC / 1286074
Location: United States, Wisconsin
Negotiable
-
Quick Look
Device: Radiographic Photospot Camera
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D33 BOARD / 1199293
Manufacturer: Siemens
Model: FLUOROSPOT H DFR
Name / Number: D33 BOARD / 1199293
Location: United States, Wisconsin
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, RELAY STATION RAS-PC / 11 63 356
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, RELAY STATION RAS-PC / 11 63 356
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, TRANSITION PANEL; (CAMTRONICS; 50078-0001D) / 12 86 066
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, TRANSITION PANEL; (CAMTRONICS; 50078-0001D) / 12 86 066
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: AC POWER DISTRIBUTION ASSEMBLY (CAMTRONICS; 70053-0002) / 12 86 090
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: AC POWER DISTRIBUTION ASSEMBLY (CAMTRONICS; 70053-0002) / 12 86 090
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, VIDEO/INPUT; (CAMTRONICS; 50049-0004D) / 12 86 124
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, VIDEO/INPUT; (CAMTRONICS; 50049-0004D) / 12 86 124
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, TEMPORAL FILTER (CAMTRONICS; 50052-0003B) / 12 86 140
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, TEMPORAL FILTER (CAMTRONICS; 50052-0003B) / 12 86 140
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, INTERPOLATOR II; (CAMTRONICS; 50060-0001C) / 12 86 157
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, INTERPOLATOR II; (CAMTRONICS; 50060-0001C) / 12 86 157
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, SYNC I/O (CAMTRONICS; 50005-0011A) / 12 86 215
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, SYNC I/O (CAMTRONICS; 50005-0011A) / 12 86 215
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, HOST P.C. BUS / 12 86 264
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, HOST P.C. BUS / 12 86 264
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, SPATIAL FILTER; (CAMTRONICS; 50051-0004A) / 12 90 217
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: BOARD, SPATIAL FILTER; (CAMTRONICS; 50051-0004A) / 12 90 217
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: POWER SUPPLY 5V (LH RESEARCH; MIGHTY MITE) / 12 92 882
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: POWER SUPPLY 5V (LH RESEARCH; MIGHTY MITE) / 12 92 882
Location: United States, New York
Negotiable
-
Quick Look
Device: Spot Film Device
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: POWER SUPPLY +/-12V (POWER ONE) / 12 92 890
Manufacturer: Siemens
Model: FLUOROSPOT H
Name / Number: POWER SUPPLY +/-12V (POWER ONE) / 12 92 890
Location: United States, New York
Negotiable
-
Spot Film Device may also be referred to as :
Digital Photospot System | X-ray Fluoroscope | X-ray Fluorograph | System, X-ray, Photofluorographic | Radiographic/Fluoroscopic Table System | Photofluoroscopes | Fluoroscopes | FluorographTips for buying Spot Film Device Parts
- Facilities should consider the types of procedures to be performed and determine the table tilt, travel, image intensifier size, and image processing methods to best suit those procedures.
- The main consideration for buyers should be the table tilt.
- Tables usually offer a 90° tilt in the plus direction, when feet are down. In the minus directions they offer 15° to 90° tilt.
- Certain procedures, such as cervical myelography, can benefit from a 90°/90° tilt.
- Manufacturers offer various longitudinal and lateral table travels. When deciding on table travel parameters, positioning the patient for various procedures is a major consideration.
- When using larger image intensifiers, more anatomy can be viewed in one image.
- Facilities need to carefully consider their needs when selecting the x-ray generator. The available generators that are commonly used for cardiac imaging include: three phase, 12 pulse, high frequency, and constant-potential generators. All can provide the high power, direct current, or very low ripple waveform required for cinefluorography.
- Space-constrained areas would benefit from high frequency generators, which are smaller and easier to install.
- Facilities should also consider the heat dissipation rate and the heat capacity of the x-ray tube anode. Only 0.2% of the electrical energy delivered to the tube is converted to x-rays, and the rest is radiated as heat - which will destroy the anode if not quickly dissipated.
- To help dissipate the heat, rotating and larger diameter anodes may be used, as well as circulated liquid cooling systems and ceramic tube envelopes.
- Using a higher anode heat capacity allows for longer fluoroscopy runs. It also provides a higher overall output, and extends x-ray tube life.
- The minimum anode heat capacity should be 1,000,000 heat units.
- Advanced interventional procedures requiring longer imaging times would benefit the most from high heat capacity tubes.
- Suppliers now offer x-ray tubes with anode heat capacities over 2,000,000 HU and heat dissipation rates of 900,000 HU/min.
- Buyers need to look at the focal spot size of the anode; a smaller focal spot provides better quality images, but the larger one dissipates heat better. Therefore, smaller ones need a larger anode heat capacity than larger focal spots do.
- Some suppliers offer two or three focal spot sizes to accommodate the variety of imaging techniques and procedures.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>







