Parts: Spot Film Device, Toshiba
![]() | Medical Part Finder | ![]() | Are you looking for a specific medical part, and you can't find it anywhere? We can find it for you, quickly and easily! | Go to Part Finder >> |
- Parts (105)
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: ciprico board / RF3563
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: quantum hard drive / RH29E
Quick Look
Manufacturer: Toshiba
Model: EPS 1000
Name / Number: BOARD / PM40-06854 / YWA3331*B
Quick Look
Manufacturer: Toshiba
Model: EPS 1000
Name / Number: BOARD 3 / PX21-02101A / YWM0663
Quick Look
Manufacturer: Toshiba
Model: EPS 1000
Name / Number: BOARD 2 / PX21-02100A / YWM0662
Quick Look
Manufacturer: Toshiba
Model: EPS 1000
Name / Number: BOARD 1 / PM40-07128 / YWM0499
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: FIRMWARE, EPS-30 CPU v.1.26 U38 / 70001267
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: FIRMWARE, EPS-30 CPU v.1.26 U39 / 70001268
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: FIRMWARE, EPS-30 CPU v.1.26 U40 / 70001269
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: FIRMWARE, EPS-30 CPU v.1.26 U41 / 70001270
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: BOARD, CIPRICO RF3563 / 82029500-H
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: BOARD, EPS-30 CPU / 97201732-02, REV. A3
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: BOARD, A/D / 97202153-01, REV. A4
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: BOARD, D/A / 97202155-01, REV. A3
Quick Look
Manufacturer: Toshiba
Model: EPS 30
Name / Number: BOARD, D/A / 97202155-02, REV. A2
Spot Film Device may also be referred to as :
Digital Photospot System | X-ray Fluoroscope | X-ray Fluorograph | System, X-ray, Photofluorographic | Radiographic/Fluoroscopic Table System | Photofluoroscopes | Fluoroscopes | FluorographIf you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (27):

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: 7x7 digital filter (60202157) / 97202157

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: alu board in room (60202103) / 9720216301

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: back plane bd / 9720124501

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: backplane VME board / 972012450

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: breaker cable / 97202267

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: cable / 97201740

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: cable / 97201741

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: cable / 97201742

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: cable / 97202265

Device: Spot Film Device
Manufacturer: Toshiba
Model: EPS 30
Name / Number: ciprico board / RF3563
Tips for buying Spot Film Device Parts
- Facilities should consider the types of procedures to be performed and determine the table tilt, travel, image intensifier size, and image processing methods to best suit those procedures.
- The main consideration for buyers should be the table tilt.
- Tables usually offer a 90° tilt in the plus direction, when feet are down. In the minus directions they offer 15° to 90° tilt.
- Certain procedures, such as cervical myelography, can benefit from a 90°/90° tilt.
- Manufacturers offer various longitudinal and lateral table travels. When deciding on table travel parameters, positioning the patient for various procedures is a major consideration.
- When using larger image intensifiers, more anatomy can be viewed in one image.
- Facilities need to carefully consider their needs when selecting the x-ray generator. The available generators that are commonly used for cardiac imaging include: three phase, 12 pulse, high frequency, and constant-potential generators. All can provide the high power, direct current, or very low ripple waveform required for cinefluorography.
- Space-constrained areas would benefit from high frequency generators, which are smaller and easier to install.
- Facilities should also consider the heat dissipation rate and the heat capacity of the x-ray tube anode. Only 0.2% of the electrical energy delivered to the tube is converted to x-rays, and the rest is radiated as heat - which will destroy the anode if not quickly dissipated.
- To help dissipate the heat, rotating and larger diameter anodes may be used, as well as circulated liquid cooling systems and ceramic tube envelopes.
- Using a higher anode heat capacity allows for longer fluoroscopy runs. It also provides a higher overall output, and extends x-ray tube life.
- The minimum anode heat capacity should be 1,000,000 heat units.
- Advanced interventional procedures requiring longer imaging times would benefit the most from high heat capacity tubes.
- Suppliers now offer x-ray tubes with anode heat capacities over 2,000,000 HU and heat dissipation rates of 900,000 HU/min.
- Buyers need to look at the focal spot size of the anode; a smaller focal spot provides better quality images, but the larger one dissipates heat better. Therefore, smaller ones need a larger anode heat capacity than larger focal spots do.
- Some suppliers offer two or three focal spot sizes to accommodate the variety of imaging techniques and procedures.











