New & Used Syringe Pump

Market Value Calculator
 
Applied Filters

Continent : Eastern Europe

  Reset
WEIGHT, kg (lb)
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Ambulatory Infusion Pump,Pump IV,Infusion Pump
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: Syringe Pump
Manufacturer: Smiths Medical
Model: Graseby MS26
Location: Poland, Wielkopolskie
Negotiable
-

Quick Look

 
Device: Syringe Pump
Manufacturer: Graseby
Model: Omnifuse
Location: Poland, Wielkopolskie
Negotiable
-

Quick Look

 
Device: Syringe Pump
Manufacturer: Graseby
Model: Omnifuse
Location: Poland, Wielkopolskie
Negotiable
-

Quick Look

 
Device: Syringe Pump
Manufacturer: Graseby
Model: 3500
Location: Poland, Wielkopolskie
Negotiable
-

Quick Look

 
Device: Syringe Pump
Manufacturer: Baxter
Model: Flo-Gard GSP
Location: Poland, Lubelskie
450
-

Quick Look

 
Device: Syringe Pump
Manufacturer: B Braun Mcgaw
Model: PERFUSOR compact
Location: Poland, Wielkopolskie
Negotiable
-

Quick Look

 
Device: Syringe Pump
Manufacturer: Graseby
Model: 3300PCA PUMP
Location: Poland, Wielkopolskie
Negotiable
-

Syringe Pump may also be referred to as :

Syringe Pump | Infusion Pump, Syringe
 

Tips for buying Syringe Pump

  1. The need for infusion sets should be determined based on the annual number of syringe pump infusions and the average infusion duration in a facility.
  2. These syringe infusion pumps should generally have adjustable flow rates with increments of 0.1 mL/hr.
  3. The syringe pumps should be designed to accommodate syringe sizes of up to 60 mL.
  4. The preferred syringe pumps are those with prime/purge control, and the ones that perform accurately to within 5% of the displayed flow rate and volume.
  5. The alarms included with the syringe infusion pumps should indicate at least the following: empty reservoir, infusion near end, infusion end, high pressure/occlusion, system malfunction, syringe unlocked, and low/depleted battery.
  6. A syringe pump should be able to store at least 200 events of error codes, alarm conditions, quantity infused, and programmable settings.
  7. An alarm-silencing mechanism for syringe pumps may be available, as long as it's temporary.
  8. These syringe infusion pumps should come with luer-lock connectors. They should provide a needleless connection for the brand of primary infusion sets used by the facility.