MedWOW / Used Medical Parts / Imaging Parts / Ultrasound, Diagnostic
 

Parts: Ultrasound, Diagnostic

Applied Filters

Condition : Refurbished

  Reset
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Ultrasound, Cardiac,Ultrasound, Portable,Ultrasonic Probes for PC

Looking for Ultrasound Probes Click Here
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured
Page: 1 2 3 4 5

Ultrasound, Diagnostic may also be referred to as :

US Portable | Ultrasound Scanner, Urology | Ultrasound Scanner, Portable | Ultrasound Scanner, General Purpose | Ultrasound Scanner, Bladder | Sonograph | Scanning System, Ultrasonic, Portable | Scanner, Ultrasonic, Portable | Portable US System | Scanner, Ultrasonic, Pediatric | Scanner, Ultrasonic, General Purpose | Small-Parts Ultrasonic Scanner | Small-Parts Scanner | Scanner, Ultrasonic, Small-Parts/Vascular | Scanner, Ultrasonic, Small-Parts | Scanner, Ultrasonic, Dedicated Linear Array | Renal Ultrasonic Scanner | Ultrasound Bladder Scanner | Scanning System, Ultrasonic, General-Purpose | Portable Ultrasonic Scanner | General-Purpose Ultrasonic Scanner | Doppler Device

If you have not found your required medical part on the above list, our suppliers can additionally offer you the following medical parts (827):

 
Item Details
Actions
Cardiac Abdominal Probe 2535 MHz

Device: Ultrasound, Diagnostic

Manufacturer: Biosound Esaote

Model: AU3

Name / Number: Cardiac Abdominal Probe / 2535 MHz

Request a quote

CLA 86 009529

Device: Ultrasound, Diagnostic

Manufacturer: Medison

Model: SonoAce 9900 (SA9900)

Name / Number: CLA 86 / 009529

Request a quote

Convex Probe PB-50C4-7BD

Device: Ultrasound, Diagnostic

Manufacturer: Medison

Model: SonoAce 6000 (SA6000)

Name / Number: Convex Probe / PB-50C4-7BD

Request a quote

Endocavity Probe PVK-720ST

Device: Ultrasound, Diagnostic

Manufacturer: Toshiba

Model: SSA-380A (PowerVision 7000)

Name / Number: Endocavity Probe / PVK-720ST

Request a quote

Footswitch  3500-0486-04

Device: Ultrasound, Diagnostic

Manufacturer: ATL

Model: UltraMark 4 (UM4)

Name / Number: Footswitch / 3500-0486-04

Request a quote

Hoffrel 2.25 MHz Probe 418

Device: Ultrasound, Diagnostic

Manufacturer: Diasonics Vingmed

Model: DRF 400

Name / Number: Hoffrel 2.25 MHz Probe / 418

Request a quote

IVT12 Endovaginal 6.5 MHz

Device: Ultrasound, Diagnostic

Manufacturer: Biosound Esaote

Model: AU3

Name / Number: IVT12 Endovaginal / 6.5 MHz

Request a quote

LH 306 14 09 734 LH 306

Device: Ultrasound, Diagnostic

Manufacturer: Siemens

Model: SONOLINE Si 450

Name / Number: LH 306 / 14 09 734 LH 306

Request a quote

Probe SMA50 20 MHz

Device: Ultrasound, Diagnostic

Manufacturer: Biosound Esaote

Model: AU4

Name / Number: Probe SMA50 20 MHz

Request a quote

SMA18 960 0048 001

Device: Ultrasound, Diagnostic

Manufacturer: Esaote

Model: Picus

Name / Number: SMA18 / 960 0048 001

Request a quote

Page: 1 2 3 4 5
 

Tips for buying Ultrasound, Diagnostic Parts

Diagnostic ultrasound is an ultrasound-based diagnostic medical imaging technique used to visualize muscles, tendons and many internal organs to capture their size, structure and any pathological lesions using real-time tomographic images.

Ultrasound has been used by radiologists and sonographers to image the human body for many years and has become one of the most widely used diagnostic tools in modern medicine. The technology is relatively inexpensive and portable, especially when compared with other techniques, such as digital radiography magnetic resonance imaging and computed tomography.

Diagnostic ultrasound is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Ultrasound images of the musculoskeletal system provide pictures of muscles, tendons, ligaments, joints and soft tissue throughout the body.

Diagnostic ultrasound is also used to visualize fetuses during routine and emergency prenatal care. Such diagnostic applications used during pregnancy are referred to as obstetric sonography.

  1. The diagnostic ultrasound involves exposing a targeted part of the body to high-frequency sound waves to produce pictures of the inside of the body. Ultrasound exams do not use ionizing radiation. Nonetheless, care should be taken to use low power settings and avoid pulsed wave scanning of the fetal brain, unless specifically indicated in high-risk pregnancies.
  2. Because ultrasound images are captured in real-time, they can show the structure and movement of the body’s internal organs, as well as blood flowing through blood vessels.
  3. Diagnostic ultrasound scanners have different Doppler-techniques to visualize arteries and veins. The most common is color Doppler or power Doppler, but also other techniques are used to show blood flow in an organ. By using pulsed wave Doppler or continuous wave Doppler blood flow, velocities can be calculated.
  4. Diagnostic ultrasound has the advantage of not needing direct contact with the inner limbs of the body. Consequently, the transducer diagnostic ultrasound part can be moved and angulated for the best possible scan view.
  5. Typical diagnostic ultrasound parts consist of front-end, beam former, back-end and application blocks.
  6. The front-end block diagnostic ultrasound part contains the transducer, the transducer elements switching system, the transmitter power amplifier, the low noise input amplifier and the analog to digital converter.
  7. The beam forming is achieved by a factory programmed integrated circuit diagnostic ultrasound part.
  8. The back-end diagnostic ultrasound part includes various imaging reconstruction and enhancement algorithms. Color Doppler, harmonic, deconvolution, non-linear processing, frequency, special compound, and scan conversion with interpolation are the most commonly used technologies.
  9. The applications become more and more important in the current trend of ultrasound imaging systems. PC-based applications are adopted in current commercial systems. They provide friendly user interface, easy-access database, remote diagnostic, and data-storage for later analysis.
  10. Phased array is widely used in the transducers of diagnostic ultrasound systems.
  11. The beam-former diagnostic ultrasound part of the transmitter determines the delay pattern and pulse train that set the desired transmit focal point. The outputs of the beam-former are then amplified by high-voltage transmit amplifiers that drive the transducers. These amplifiers may be controlled digitally to shape the transmit pulses for better energy delivery to the transducer diagnostic ultrasound part elements. Typically, multiple transmit focal regions are used.
  12. The field to be imaged is divided up, by focusing the transmitted energy at progressively deeper points in the body. The main reason for doing this is to increase the transmitted energy to points that are deeper in the body, because the signal becomes thinner and weaker as it travels into the body.
  13. In diagnostic ultrasound systems, the echo signal sampling is the start of the back-end process. The acquired signals can be combined to extract the useful part of the signal. Next, a user-controlled amplifier sets the information signals amplitude, in order to achieve the best image.
  14. The application block of the diagnostic ultrasound is designed to process the basic information in various ways. It can, for example, generate 2D, 3D and 4D images, harmonic imaging (the second harmonic image has greaterer clarity, contrast and detailing than the fundamental frequency range) and color Doppler. It can also improve the image quality by filtering out noise and artifacts.
  15. Finally, the scan conversion takes the filtered data of the diagnostic ultrasound and puts it into a presentable form for display. It converts the polar coordinates to rectangular pixel positions. Normally this interpolation is done at the same time during conversion.

Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>