New & Used Ventilator, Pediatric, Draeger
Market Value Calculator
Applied Filters
Model
Continent
Condition
Price Range (USD)
Seller's Business Type
Nebulizer
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Ventilator, Intensive Care,Ventilator, Portable,Transport Ventilator
- Complete Systems (22)
- Parts (7)
Item Details
Seller details
Item Price (USD)
Year manufactured
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 8000
Manufacturer: Draeger
Model: Babylog 8000
Location: Poland, Wielkopolskie
Negotiable
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: Evita XL
Manufacturer: Draeger
Model: Evita XL
Location: Germany, Bavaria
Negotiable
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 8000
Manufacturer: Draeger
Model: Babylog 8000
Location: Germany, Berlin
3,500 
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 2
Manufacturer: Draeger
Model: Babylog 2
Location: United Kingdom, Northamptonshire
316 
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 8000
Manufacturer: Draeger
Model: Babylog 8000
Location: United States, Florida
Negotiable
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: MicroVent
Manufacturer: Draeger
Model: MicroVent
Location: United States, Florida
Negotiable
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: Evita 2 dura
Manufacturer: Draeger
Model: Evita 2 dura
Location: United States, Florida
Negotiable
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 2
Manufacturer: Draeger
Model: Babylog 2
Location: Germany, North Rhine-Westphalia
Rating: 93%
Rating: 93%
1,191
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 2
Manufacturer: Draeger
Model: Babylog 2
Location: Germany, North Rhine-Westphalia
Rating: 93%
Rating: 93%
993
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 1
Manufacturer: Draeger
Model: Babylog 1
Location: Germany, Bavaria
Rating: 93%
Rating: 93%
1,020
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: Savina
Manufacturer: Draeger
Model: Savina
Location: India, Tamil Nadu
Negotiable
-
Quick Look
Device: Ventilator, Pediatric
Manufacturer: Draeger
Model: Babylog 8000 plus
Manufacturer: Draeger
Model: Babylog 8000 plus
Location: United States, Missouri
4,200
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: Savina
Manufacturer: Draeger
Model: Savina
Location: United Arab Emirates
6,500
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: Evita 4
Manufacturer: Draeger
Model: Evita 4
Location: United Arab Emirates
8,500
-
Quick Look
Device: Ventilator, Intensive Care
Manufacturer: Draeger
Model: Evita 2 dura
Manufacturer: Draeger
Model: Evita 2 dura
Location: United Arab Emirates
7,500
-
Ventilator, Pediatric may also be referred to as :
High-Frequency Ventilator | Ventilator, Intensive Care, Neonatal/Pediatric | Ventilator, Time-Cycled | Ventilator, Pediatric | Ventilator, Neonatal | Ventilator, Continuous | Time-Cycled Ventilator | Positive Pressure Ventilator | Pediatric Ventilator | Neonatal Ventilator | Continuous Ventilator | Infant VentilatorTips for buying Ventilator, Pediatric
- Pediatric ventilators should have time-cycled, pressure-limited operation and should offer assist/control and SIMV ventilation modes. Neonatal ventilators should also have the supplemental functions of pressure support or leak compensation and provide inverse I:E ratio, PEEP, and CPAP support.
- The following measures should be monitored by the pediatric ventilator: airway pressure, respiratory rate, I:E ratio, and minute volume; controls should be available for FiO2, PEEP/CPAP, flow, pressure, pressure level, tidal volume, inspiratory time, I:E ratio, pressure support, sensitivity, and pressure limit.
- Pediatric ventilators and neonatal ventilators should have audible and visual alarms available for the following events: peak inspiratory pressure (high and low), minute volume respiratory rate, gas supply loss, and power failure, all alarms should be distinct and easily identified.
- If users can adjust the alarm volume, they should not be able to turn it down so that the alarm is inaudible. When the alarm-silencing feature is acceptable, the alarm must reactivate automatically if the condition is not corrected. Whenever the alarm is silenced, a clear visual display should indicate which pediatric ventilator alarm is disabled.
- An oxygen analyzer should monitor the delivered oxygen or oxygen/air mixture. This should either be included with the pediatric ventilator or purchased separately and placed in line with the breathing circuit. Neonatal ventilator and pediatric ventilator alarms should be displayed or sound for concentrations outside the acceptable ranges.
- All controls should be clear with easy-to-understand functions. Misinterpretation of displays and control settings should not occur. Controls should be protected against accidental setting and sealed against fluid penetration. Fluid spills should not affect patient and operator safety and system performance.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>

















