Used Veterinary Monitor - Biolight - M7000
Item 715661891
Are you the Seller of this medical device/part? Log In for more options.
| Status: | Open |
| Item type: | Complete System |
| Category: | Veterinary |
| Device: | Veterinary Monitor |
| Manufacturer: | Biolight |
| Model: | M7000 |
| Condition: | Never used |
| Year manufactured: | 2010 |
| Location: | United States, Illinois |
| Availability: | Immediate |
| Quantity: | 1 available |
| Unit Price: | Negotiable |
![]() | Contact the Seller | ![]() |
Item Description
Product Description
Used in hospital and clinique for monitoring patient's ECG, RESP, NIBP, SPO2, TEMP parameters
Product Feature
7’’ TFT LCD display, high resolution,
Built-in rechargeable battery
User-Friendly operational window
60s full disclosure of ECG playback
48 hours tabular and graphic trends & data storage
Digital SPO2, high capacity against interference of ESU, motion & low infusion
Isolated against defibrillation effect
Wireless or wire communicable with central station system
Parameter : 5 Lead ECG, RESP, Digital SPO2, NIBP, TEMP
Product Specification/Models
Technical specifications
Safety: IEC60601 (GB9706)
Dimension: 256mm (W) x 209mm (H) x 185mm(D)
Weight: 4 Kgs (with battery)
Power Supply : 100~240V; AC: 47~ 63 Hz
12 VDC
Alarm Indication: Visual and audible alarm
ECG
Leads: I, II, III, aVR, aVL, aVF, Cx
Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
Input impedance: =5MO (d.c.~60Hz)
Common Mode Rejection Ratio: =85dB(diagnostic mode)
=105dB(monitoring & surgica mode)
Bandwith: 0.5-40Hz (monitoring mode)
0.05-120Hz(diagnostic mode)
1-25Hz (surgical mode)
Protection: Segregation breakdown voltage 4000VAC, 50/60Hz
Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
Indication of Detachment of electrodes: Available
Playback of Cardiogram: Available
Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range:10-300BPM
Accuracy: ±1BPM
NIBP
Method: Automatic oscillometric
Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
Measurement : Systolic pressure/diastolic pressure/mean
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonate: 10-135mmHg
Unit: mmHg / Kpa selectable
Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8,12 hours
600 groups of NIBP measuring data review
Used in hospital and clinique for monitoring patient's ECG, RESP, NIBP, SPO2, TEMP parameters
Product Feature
7’’ TFT LCD display, high resolution,
Built-in rechargeable battery
User-Friendly operational window
60s full disclosure of ECG playback
48 hours tabular and graphic trends & data storage
Digital SPO2, high capacity against interference of ESU, motion & low infusion
Isolated against defibrillation effect
Wireless or wire communicable with central station system
Parameter : 5 Lead ECG, RESP, Digital SPO2, NIBP, TEMP
Product Specification/Models
Technical specifications
Safety: IEC60601 (GB9706)
Dimension: 256mm (W) x 209mm (H) x 185mm(D)
Weight: 4 Kgs (with battery)
Power Supply : 100~240V; AC: 47~ 63 Hz
12 VDC
Alarm Indication: Visual and audible alarm
ECG
Leads: I, II, III, aVR, aVL, aVF, Cx
Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
Input impedance: =5MO (d.c.~60Hz)
Common Mode Rejection Ratio: =85dB(diagnostic mode)
=105dB(monitoring & surgica mode)
Bandwith: 0.5-40Hz (monitoring mode)
0.05-120Hz(diagnostic mode)
1-25Hz (surgical mode)
Protection: Segregation breakdown voltage 4000VAC, 50/60Hz
Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
Indication of Detachment of electrodes: Available
Playback of Cardiogram: Available
Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range:10-300BPM
Accuracy: ±1BPM
NIBP
Method: Automatic oscillometric
Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
Measurement : Systolic pressure/diastolic pressure/mean
Range: Adult: 10-270mmHg
Pediatric: 10-235mmHg
Neonate: 10-135mmHg
Unit: mmHg / Kpa selectable
Auto Measurement: 1,2,3,4,5,10,15,20,30,45,60,90 minutes, 2,4,8,12 hours
600 groups of NIBP measuring data review
Sale Information
| Payment Payment methods: Bank Transfer, Cash, Check, Credit Card, Debit Card, MedWOW SafeTrade, Letter of Credit, PayPal, Trade in Advance payment percentage: 100% Return Policy Does the seller accept returns? Yes Return valid for: 7 days after buyer's receipt of the item Allowed refund types: Money back, Exchange, Credit Note Return shipping & handling will be paid by the buyer The item is not packed Inspection Seller allows inspection of item? Yes Available for inspection from: Immediate Warranty Period: 24 months Warranty type: Labor & Material |
All item information on this page has been supplied by seller and MedWOW cannot guarantee its accuracy.
Didn't find the medical device you're looking for? Post a Buying Request
A buying lead is an excellent way to reach worldwide medical equipment sellers!
- Fill in a simple form, giving us details about the medical device you are searching for.
- Receive competitive quotes from global sellers that have the item you are searching for in their inventory.
- Choose the best and most suitable quote for you!
View more Veterinary Monitor devices for sale


Seller details
Location: United States, Illinois
Business type: Distributor
Num. of items sold: 9 Learn More About This Seller
![]() | Get a D&B Report >> |
Buying Toolbox
Track this Item
Required quantity
Quantity available: 1
Please enter the quantity you would like to purchase:
Quantity must be between 1 - 1
Please select your choice
Popular Searches
Use of this website constitutes acceptance of the MedWOW User Agreement and Privacy Policy.
© 2012 All rights reserved, MedWOW Ltd. Global online marketplace for buying and selling used medical equipment and medical equipment parts.