Parts: X-ray Generator

More Filters
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Analog,Rad Room, Digital,Chest X-ray
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured

Quick Look

 
Device: X-ray Generator
Manufacturer: Siemens
Model: Polymat 65
Name / Number: X-Ray Tube / 3345217
Premium User
Location: United States, Washington
Rating: 89%
795
-
Page: 1 2 3 4 5
The model & manufacturer of the marked items have changed due to an acquisition between companies, and are also known as:
Current Manufacturer / Model Name Alternative Manufacturer / Model Name
Gendex / GX 525 Del Medical Systems / GX 525

X-ray Generator may also be referred to as :

Radiographic-Tomographic System, Linear | Radiographic/Fluoroscopic Unit Accessories | Radiographic/Fluoroscopic System, General-Purpose, Camera, Radiographic Photospot | Radiographic/Fluoroscopic System, Angiographic/Interventional, Cardiovascular | Radiographic System, Film/Digital (CR) | Radiographic Generator | Fluoroscopic Generator

If you have not found your required medical part on the above list, our suppliers can additionally offer you the following medical parts (1,175):

 
Item Details
Actions
AEC PCB 208094

Device: X-ray Generator

Manufacturer: Bennett X-ray

Model: HFQ-1250P

Name / Number: AEC PCB / 208094

Request a quote

Collimator 3121B 3121B

Device: X-ray Generator

Manufacturer: Picker

Model: GX 650

Name / Number: Collimator 3121B / 3121B

Request a quote

Fluror Control  451210774504

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: Fluror Control / 451210774504

Request a quote

P38DE X-ray Tube 0.6-1.2P38DE -85(s)

Device: X-ray Generator

Manufacturer: Shimadzu

Model: UD150L-30EX

Name / Number: P38DE X-ray Tube / 0.6-1.2P38DE -85(s)

Request a quote

X-ray Tube 1-2P13DK -85

Device: X-ray Generator

Manufacturer: Shimadzu

Model: UD150L-30EX

Name / Number: X-ray Tube / 1-2P13DK -85

Request a quote

072Z011

Device: X-ray Generator

Manufacturer: GE Healthcare

Model: Phasix 80

Name / Number: 072Z011

Request a quote

54056P91

Device: X-ray Generator

Manufacturer: GE Healthcare

Model: Phasix 80

Name / Number: 54056P91

Request a quote

(37559/22m) board 823612G015

Device: X-ray Generator

Manufacturer: GE Healthcare

Model: Phasix 80

Name / Number: (37559/22m) board / 823612G015

Request a quote

(e01) pcb Y714622

Device: X-ray Generator

Manufacturer: GE Healthcare

Model: Phasix 80

Name / Number: (e01) pcb / Y714622

Request a quote

(e02) pcb 714639

Device: X-ray Generator

Manufacturer: GE Healthcare

Model: Phasix 80

Name / Number: (e02) pcb / 714639

Request a quote

Page: 1 2 3 4 5
 

Tips for buying X-ray Generator Parts

  1. Facilities should select power rating and timing capabilities based on the types of examinations to be performed and the operating technique factors required with the type of x-ray generator selected.
  2. Power setting is the main factor when dealing with these x-ray generator units.
  3. Low power x-ray generators are capable of the full range of x-ray exposures.
  4. Shorter exposure times can be used with higher power. With shorter exposure times there is less chance of movement artifacts.
  5. A 50 kW-generator is sufficient if the generator is used predominantly for extremity and chest imaging.
  6. When large patients are expected, particularly in Radiographic/Fluoroscopic system applications, higher power generators are needed.
  7. If a heavy workload of abdominal imaging is expected, then an 80 kW generator should be considered.
  8. When choosing a Radiographic-Tomographic system unit, facilities should consider the secondary waveform type, timing capabilities, and compatibility with other system components.
  9. The secondary waveform type determines the efficiency of x-ray production, including the magnitude of ripple and the ratio of average to peak x-ray tube voltage.
  10. Secondary waveforms that are single-phase, full-wave rectified provide the least efficient production of x-rays, which results in longer radiographic exposure times and higher patient radiation exposure.
  11. Single-phase x-ray generators cause increased x-ray tube anode heating, and therefore restrict small focal spot examinations and reduce tube life.
  12. Three-phase x-ray generators allow higher mA exposures at shorter exposure times, reduce motion un-sharpness, and produce higher-quality radiographs for many examinations.
  13. Facilities should add power installation costs to the project budget if three-phase power service is not available at the planned location.
  14. A procedure using a three-phase or high frequency x-ray generator needs lower kVp and/or mAs than the same one using a single-phase x-ray generator.
  15. Routine radiographic, angiographic, fluoroscopic, and tomographic procedures vary in their kVp and mAs requirements, so all features of Radiographic-Tomographic Systems and Radiographic/Fluoroscopic Systems must be taken into consideration.
  16. Putting the x-ray generator too far away from the x-ray tube may cause distortions in voltage waveforms and timing responses caused by capacitance in excessively long high-voltage cables.
  17. Facilities must select x-ray generator components for compatibility as an integrated system. It is specifically critical to choose compatible x-ray tubes and generators to fully utilize all features of both components.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>