Parts: X-ray Generator, Philips

Applied Filters

Manufacturer : Philips

  Reset
loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Analog,Rad Room, Digital,Chest X-ray
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured
Page: 1 2 3 4 5

X-ray Generator may also be referred to as :

Radiographic-Tomographic System, Linear | Radiographic/Fluoroscopic Unit Accessories | Radiographic/Fluoroscopic System, General-Purpose, Camera, Radiographic Photospot | Radiographic/Fluoroscopic System, Angiographic/Interventional, Cardiovascular | Radiographic System, Film/Digital (CR) | Radiographic Generator | Fluoroscopic Generator

If you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (65):

 
Item Details
Actions
Fluror Control  451210774504

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: Fluror Control / 451210774504

BD 451210805305

Device: X-ray Generator

Manufacturer: Philips

Model: Optimus 50

Name / Number: BD / 451210805305

BOARD 451210779101

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: BOARD / 451210779101

BOARD 452210815052

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: BOARD / 452210815052

BOARD 452210819548

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: BOARD / 452210819548

CHAMBER SELECT BD. 451210803961

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: CHAMBER SELECT BD. / 451210803961

CINE CONVERTOR 452210783811

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: CINE CONVERTOR / 452210783811

CONSOLE 989600008741

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: CONSOLE / 989600008741

CONTACTOR 242213101546

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: CONTACTOR / 242213101546

CONVERTER CTRL MOD 451210803662

Device: X-ray Generator

Manufacturer: Philips

Model: Super 80 CP

Name / Number: CONVERTER CTRL MOD / 451210803662

Page: 1 2 3 4 5
 

Tips for buying X-ray Generator Parts

  1. Facilities should select power rating and timing capabilities based on the types of examinations to be performed and the operating technique factors required with the type of x-ray generator selected.
  2. Power setting is the main factor when dealing with these x-ray generator units.
  3. Low power x-ray generators are capable of the full range of x-ray exposures.
  4. Shorter exposure times can be used with higher power. With shorter exposure times there is less chance of movement artifacts.
  5. A 50 kW-generator is sufficient if the generator is used predominantly for extremity and chest imaging.
  6. When large patients are expected, particularly in Radiographic/Fluoroscopic system applications, higher power generators are needed.
  7. If a heavy workload of abdominal imaging is expected, then an 80 kW generator should be considered.
  8. When choosing a Radiographic-Tomographic system unit, facilities should consider the secondary waveform type, timing capabilities, and compatibility with other system components.
  9. The secondary waveform type determines the efficiency of x-ray production, including the magnitude of ripple and the ratio of average to peak x-ray tube voltage.
  10. Secondary waveforms that are single-phase, full-wave rectified provide the least efficient production of x-rays, which results in longer radiographic exposure times and higher patient radiation exposure.
  11. Single-phase x-ray generators cause increased x-ray tube anode heating, and therefore restrict small focal spot examinations and reduce tube life.
  12. Three-phase x-ray generators allow higher mA exposures at shorter exposure times, reduce motion un-sharpness, and produce higher-quality radiographs for many examinations.
  13. Facilities should add power installation costs to the project budget if three-phase power service is not available at the planned location.
  14. A procedure using a three-phase or high frequency x-ray generator needs lower kVp and/or mAs than the same one using a single-phase x-ray generator.
  15. Routine radiographic, angiographic, fluoroscopic, and tomographic procedures vary in their kVp and mAs requirements, so all features of Radiographic-Tomographic Systems and Radiographic/Fluoroscopic Systems must be taken into consideration.
  16. Putting the x-ray generator too far away from the x-ray tube may cause distortions in voltage waveforms and timing responses caused by capacitance in excessively long high-voltage cables.
  17. Facilities must select x-ray generator components for compatibility as an integrated system. It is specifically critical to choose compatible x-ray tubes and generators to fully utilize all features of both components.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>