loupe Medical Part Finder Search for part Are you looking for a specific medical part, and you can't find it anywhere?
We can find it for you, quickly and easily!
Go to Part Finder >>
 
Please Note: Search results for this device do not include the following devices, please select the relevant device if it is of interest to you: Rad Room, Analog,Rad Room, Digital,Chest X-ray
 
 
 
 
Item Details
Seller details
Item Price (USD)
Year manufactured
Page: 1 2 3 4 5

X-ray Generator may also be referred to as :

Radiographic-Tomographic System, Linear | Radiographic/Fluoroscopic Unit Accessories | Radiographic/Fluoroscopic System, General-Purpose, Camera, Radiographic Photospot | Radiographic/Fluoroscopic System, Angiographic/Interventional, Cardiovascular | Radiographic System, Film/Digital (CR) | Radiographic Generator | Fluoroscopic Generator

If you have not found your required medical part at the list above, our suppliers can offer you the following medical parts (39):

 
Item Details
Actions
Collimator 3121B 3121B

Device: X-ray Generator

Manufacturer: Picker

Model: GX 650

Name / Number: Collimator 3121B / 3121B

2pst 24 dcv coil relay T19A141

Device: X-ray Generator

Manufacturer: Picker

Model: GX 1050

Name / Number: 2pst 24 dcv coil relay / T19A141

2pst 24 dcv coil relay T19A141

Device: X-ray Generator

Manufacturer: Picker

Model: GX 1050

Name / Number: 2pst 24 dcv coil relay / T19A141

300ma meter T69136

Device: X-ray Generator

Manufacturer: Picker

Model: GX 325

Name / Number: 300ma meter / T69136

bracket magnet assy 188395

Device: X-ray Generator

Manufacturer: Picker

Model: Vector II

Name / Number: bracket magnet assy / 188395

buzzer 24vac T19A148

Device: X-ray Generator

Manufacturer: Picker

Model: GX 1050

Name / Number: buzzer 24vac / T19A148

capacitor 21-25 mfd / 150v  T45817

Device: X-ray Generator

Manufacturer: Picker

Model: Vector II

Name / Number: capacitor 21-25 mfd / 150v / T45817

capacitor 2900mfd 40vdc  T45731

Device: X-ray Generator

Manufacturer: Picker

Model: GX 650

Name / Number: capacitor 2900mfd 40vdc / T45731

capacitor 4000mf, 30wvdc T45732

Device: X-ray Generator

Manufacturer: Picker

Model: GX 650

Name / Number: capacitor 4000mf, 30wvdc / T45732

capacitor 5200mfd 50vdc / capacitor 52mfd 50vdc  T45314

Device: X-ray Generator

Manufacturer: Picker

Model: GX 1050

Name / Number: capacitor 5200mfd 50vdc / capacitor 52mfd 50vdc / T45314

Page: 1 2 3 4
 

Tips for buying X-ray Generator Parts

  1. Facilities should select power rating and timing capabilities based on the types of examinations to be performed and the operating technique factors required with the type of x-ray generator selected.
  2. Power setting is the main factor when dealing with these x-ray generator units.
  3. Low power x-ray generators are capable of the full range of x-ray exposures.
  4. Shorter exposure times can be used with higher power. With shorter exposure times there is less chance of movement artifacts.
  5. A 50 kW-generator is sufficient if the generator is used predominantly for extremity and chest imaging.
  6. When large patients are expected, particularly in Radiographic/Fluoroscopic system applications, higher power generators are needed.
  7. If a heavy workload of abdominal imaging is expected, then an 80 kW generator should be considered.
  8. When choosing a Radiographic-Tomographic system unit, facilities should consider the secondary waveform type, timing capabilities, and compatibility with other system components.
  9. The secondary waveform type determines the efficiency of x-ray production, including the magnitude of ripple and the ratio of average to peak x-ray tube voltage.
  10. Secondary waveforms that are single-phase, full-wave rectified provide the least efficient production of x-rays, which results in longer radiographic exposure times and higher patient radiation exposure.
  11. Single-phase x-ray generators cause increased x-ray tube anode heating, and therefore restrict small focal spot examinations and reduce tube life.
  12. Three-phase x-ray generators allow higher mA exposures at shorter exposure times, reduce motion un-sharpness, and produce higher-quality radiographs for many examinations.
  13. Facilities should add power installation costs to the project budget if three-phase power service is not available at the planned location.
  14. A procedure using a three-phase or high frequency x-ray generator needs lower kVp and/or mAs than the same one using a single-phase x-ray generator.
  15. Routine radiographic, angiographic, fluoroscopic, and tomographic procedures vary in their kVp and mAs requirements, so all features of Radiographic-Tomographic Systems and Radiographic/Fluoroscopic Systems must be taken into consideration.
  16. Putting the x-ray generator too far away from the x-ray tube may cause distortions in voltage waveforms and timing responses caused by capacitance in excessively long high-voltage cables.
  17. Facilities must select x-ray generator components for compatibility as an integrated system. It is specifically critical to choose compatible x-ray tubes and generators to fully utilize all features of both components.
Read more valuable tips on the Medical Equipment Buying Guide by MedWOW >>